Ot-systems ET1111P series Instrukcja Użytkownika Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 2
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1
ET1111P Series
Industrial 10/100BASE-TX to 100BASE-FX Ethernet Media Converter with PoE/PSE
V3
2
The Port Status LEDs, Wall Mounting Kits, Optional DIN-Rail Kits
LED
State
Indication
PWR
Steady
Power on.
Off
Power off.
Power over Ethernet (PoE)
PoE
Steady
Power Device (PD) is connected.
Flashing
Power Device is under detection stage
Off
Power Device (PD) is disconnected.
10/100Base-TX, 100Base-FX
Link/ACT
Steady
A valid network connection established.
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Off
Ethernet connection is not established
SPD
Steady
100 Mbps network equipment is
connected
Off
10 Mbps network equipment is
connected or Ethernet connection is not
established
Functional Description
Meets EN55022: 2006+A1: 2007 EMC standard.
Supports IEEE802.3af Power over Ethernet (PoE) Power Sourcing Equipment (PSE).
Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, Full/Half-duplex, Auto-Negotiation, Auto MDI/MDIX.
100Base-FX: Multi/Single mode SC type; WDM 100Base-FX: Multi/Single mode SC type.
Supports 1024 MAC addresses. Provides 128K bits buffer memory.
Power Supply: 48VDC Terminal Block power input.
Operating voltage and Max. current consumption: 0.44A @ 48VDC or -0.44A @ -48VDC. Power consumption: 21.12W
Max.
-10°C to 60°C (14°F to 140°F) operating temperature range
Supports Wall Mounting installation.
Assembly, Startup, and Dismantling
Wall Mounting installation
Assembly: Securely fasten the wall-mount kits to the bottom of module by using the provided screws (4 pcs)
Mount the standalone unit onto a fixture, e.g. a plank, (either on the wall or on a flat surface) with at least 2 screws piercing
through the holes on the mounting frame to secure it in position.
Startup: Connect the supply voltage to start up the Media Converter via the terminal block (or DC JACK).
Dismantling: Locate and remove the securing screws. Usually, but not limited to, at least 2 screws.
Manual Earth Green manual is available on our website www.ot-systems.com